Zodiac G2 Instruction Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
SECTION 4 – TROUBLESHOOTING GUIDE
14
MECHANICAL
(MACHINE STOPS OR MOVES SLUGGISHLY)
1. Turn the filter system off and check all the connections of the ZODIAC
GENIE SERIES II™ to the skimmer.
2. Remove the ZODIAC GENIE SERIES II™ head from the hose, turn it upside
down and inspect for debris blocking the diaphragm.
3. Backwash or clean the filter and clean pump and skimmer baskets of all
debris. Turn the filter system on and check that there is good flow.
NOTE: In cold water 15°c or less, water flow through the ZODIAC GENIE
SERIES II™ must be increased to compensate for the reduced flexibility of
the hose and diaphragm.
4. If the ZODIAC GENIE SERIES II™ still does not move, lift the hose out of
the water, 1 metre at a time, while filtration system is running. A crack in
the hose can be detected by a hissing noise. Replace hose.
5. If the above steps do not resolve the problem, the pool filtration system
is probably not supplying the water flow necessary to propel the
ZODIAC GENIE SERIES II™.
6. Have a qualified pool service person inspect your pump impeller, pump motor,
filter tank and elements or plumbing for blockage or leaks.
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22

Comments to this Manuals

No comments