Installation and Operation Manual
|
Legacy™ Model LRZM Pool/Spa Heater
LRZ Pressure Drop vs Flow
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
0 100 200 300 400 500
Water Flow (LPM)
Pressure Drop (m H2O)
LRZ125
LRZ250
LRZ175
LRZ325
LRZ400
 
The Legacy Model LRZ millivolt heater is
shipped with water connections on the right side,
but can be modied in the eld to provide left-side
water connections. This procedure involves remov-
ing the heat exchanger headers and reinstalling them
on opposite ends of the tube assembly. Some of the
heater wiring must be disconnected and re-routed, so
this procedure must be done only by a trained service
technician. Heat exchanger reversals are generally
done before the installation of power and water to the
heater. If you need to reverse the heat exchanger on
a previously installed heater be sure that all electri-
cal power, the gas supply and water supply have been
turned off before starting the procedure. These instruc-
tions have been written to include the steps needed
when reversing the water connections on an existing
installation. If you are reversing the headers on a new
installation, some steps will be ignored.
When an automatic chemical feeder is installed
in the plumbing, it must be installed downstream of
the heater (see Section 5.7). A check valve must be
installed between the heater and the chemical feeder to
prevent back-siphoning of chemically saturated water
into the heater where it will damage the components.
 
The inlet/outlet header of the Legacy Model LRZ
millivolt heater comes equipped with an automatic
ow control valve. The automatic ow control valve
maintains the proper ow through the heater at rates
up to approximately 475 lpm. If the lter system ow
rate is higher than approximately 475 lpm, install a
manual bypass valve (see Figure 6), then perform a
temperature rise test (see Section 11.6) and adjust the
ow using the bypass valve until the proper tempera-
ture rise is obtained.
AQUAPURE
MANUAL BY-PASS DETAIL
MANUAL BY-PASS IS USED
WHEN FILTRATION RATE
EXCEEDS 125 GPM
 
 