4.2/ pH set point
The pH set point is the value to which the Zodiac TRi will adjust the pH in the swimming
pool water. This value is always displayed on the LCD screen. The default setting for
the TRi PRO module is 7,2 pH. This value corresponds to the ideal compromise so as
to achieve optimal effi ciency in terms of water disinfection, but it can be changed to
adapt to specifi c pool conditions and requirements.
To change the pH set point:
1. Ensure that the pH sensor has been calibrated (see above procedure).
2. From the default display on the LCD screen, press the
button.
3. Use the buttons to display pH/ACL SETUP, then press .
4. Use the
buttons to display pH SETPOINT, then press .
5. Use the
buttons in order to change the set point value and press
to validate.
6. Press
button 2 times or wait 30 seconds for the TRi power pack to
return to the default display on the LCD screen.
4.3/ Setting the pool size
To ensure that the pH is regulated under the best conditions for your pool,
it is necessary to adapt the settings of the peristaltic pump according to the
volume of water in your pool so as to release only the required quantity of pH
minus (dosing cycle adjustment). This setting is performed only once when
activating the TRi PRO module for the fi rst time, it is not necessary to change
it thereafter.
It is possible to set 4 different levels corresponding to 4 sizes of swimming
pool. List of sizes and corresponding volumes of pool water:
- Size #1 : For small pools up to 60 m
3
- Size #2 : For mid-size pools between 60 and 90 m
3
- Size #3 : For large pools between 90 and 120 m
3
- Size #4 : For very large pools more than 120 m
3
The above values are only indications, the exact values may vary according
to the conditions of use. However, it is recommended not to “over-size” the
setting so as to avoid using too much pH minus.
NOTE: For safety reasons, default pool size setting is #1 (lowest level).
To set the pool size:
1. From the default display on the LCD screen, press the button.
2. Use the buttons to display pH/ACL SETUP, then press .
3. Use the
buttons to display SET POOL SIZE, then press .
4. Use the
buttons to select the pool size corresponding to your
pool volume (default setting is #1).
5. Press
to confi rm your choice then press button 2 times or wait
30 seconds for the TRi power pack to return to the default display on the
LCD screen.
32
NOTE: One dose of pH minus is released in the pool every 2 hours (when
ltration system and TRi unit are both operating).
WARNING! It is not recommended to oversize the pool size setting in
order to avoid pH minus overdosing.
4.4/ ACL sensor calibrating procedure
1. Remove the ACL sensor (red) from its holder onto the POD (manually
unscrew the tightening collar). Rinse the extremity of the pH sensor with
clear water and shake it so as to remove any excess water. Do not touch or
use a cloth to wipe the glass bulb on the extremity of the pH sensor! (1).
2. Place ACL sensor in a sample of ‘ORP 700 mV’ orange buffer solution
(provided, see picture below).
3. Leave the ACL sensor immersed in the buffer solution for approximately 5
minutes in order to ensure a reliable measurement (2).
4. From the default display on the LCD screen, press the button.
5. Use the buttons to display pH/ACL SETUP, then press .
6. Use the
buttons to display CALIBRATE ACL, then press .
7. Displayed ACL value on the LCD screen CURRENT ACL could have 3 different
values : HIGH, LOW or OK. Press
to start the
calibration process (see pictures below) (3).
8. Once the calibration is completed, ACL value
should be OK (CURRENT ACL).
If the displayed value is not OK, repeat steps 1 to 7
(4)
.
9. Press button twice or wait 30 seconds, the
TRi power pack will return to the default display
on the LCD screen.
IMPORTANT NOTES:
- In order to ensure that the Zodiac TRi remains fully effi cient, it is
recommended to perform a calibration at least once every two months
during the season of pool use.
- Ensure that the ACL sensor is perfectly clean before starting a calibration
operation (Refer to chapter 8 / ‘pH & ACL sensors cleaning’). Then rinse it
with clear water, this will ensure that the calibration will be more accurate.
!
!