ON/OFF
37
¬
Solutions :
- Check the pump, the lter and the skimmer(s). Clean them if necessary.
- Check the correct operation of the ow sensor.
- Check the wiring connections (cell and ow sensor).
8.3 ‘CHECK CELL
¬
Interpretation:
e electrode is dirty, scaled and/or used.
¬
Possible causes:
Faulty ltering (pre-lter or diaphragm), water too hard (TH), electrode too old.
¬
Solutions :
- Clean and/or check the ltering system (pump & lter).
- Check the TH level and add calcium sequestering products if needed. Change the polarity inversion cycle
intervals if the TH > 40 °f (400 ppm) (see the important note in the ‘Inspecting and cleaning the electrode’ paragraph).
- Replace the electrode by an equivalent new one.
8.4 ‘OUTPUT FALT
¬
Interpretation:
ere is a problem with the internal power supply to the TRi command box.
¬
Possible causes:
- Cell power supply cable disconnected or badly connected.
- Internal power problem in the command box following an external electrical incident.
¬
Solutions :
- Turn the TRi chlorinator o ( and cut o the power supply to the command box; then check that all the
wires are correctly connected (mains, cell…)
- Contact your reseller.
8.5 ‘CLEANING’
¬
Interpretation:
e TRi chlorinator is inversing the cell polarity. is is an automatic self-cleaning cycle; the message is not an error
but is only for information.
¬
Solution :
Wait for about 10 minutes and chlorine production will resume automatically at the set levels.