Figure 1. Jandy AE-Ti Heat Pumps Dimensions
Correct installation is required to assure safe
operation. The requirements for Jandy heat pumps
include the following:
1. Field assembly (if required).
2. Appropriate site location and clearances.
3. Sufcient air ventilation.
4. Proper electrical wiring.
5. Adequate water ow.
This manual provides the information needed to
meet these requirements. Review all application and
installation procedures completely before continuing the
installation.
2.2 Location Requirements
2.2.1 Introduction
NOTE: Indoor installations require special
considerations for condensate drainage and
venting the cold air produced by the heat
pump. Contact the Jandy Heat Pump Technical
Service Department at (954) 970-4800.
CAUTION
When pool equipment is located below the pool
surface, a leak from any component can cause
large scale water loss or ooding. Waterpik
Technologies cannot be responsible for such
water loss or ooding or resulting damage.
ATTENTION
Lorsque l’équipement d’une piscine est situé
sous la surface de l’eau, une fuite provenant de
n’importe quel élément peut causer une perte
d’eau importante ou une inondation. Waterpik
Technologies n’est pas responsable des pertes
d’eau, des inondations ou des avaries causées
par une installation ou un entretien inadéquat.
Avoid placing the heat pump in locations where
it can cause damage by water or condensate leakage. If
this is not possible, provide a suitable drain pan to catch
and divert any leakage.
All criteria given in the following sections reflect
minimum clearances. However, each installation must
also be evaluated, taking into account the prevailing
local conditions such as proximity and height of walls,
and proximity to public access areas.
2.2.2 Clearances
The heat pump must be placed to provide
clearances on all sides for maintenance and inspection.
See Table 1.
At least 24” (61cm) access must be available in
front of the heat pump for service.
If the heat pump is to be installed in a garage
or under a vertical overhang, the unit must have a
minimum of 5 feet clearance from the top of the heat
pump.
This heat pump must be installed at least 5 feet
(1.52 meters) from the inside wall of the pool or spa
unless the heat pump is separated from the pool or spa
by a 5 foot high solid fence or other permanent barrier.