Zodiac TRI CHLORINE GENERATOR Installation Guide

Browse online or download Installation Guide for Above ground pool accessories Zodiac TRI CHLORINE GENERATOR. Zodiac TRI CHLORINE GENERATOR Installation guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
23
Contents
We would like to thank you for having chosen the ZODIAC TRi salt water chlorinator for your pool maintenance.
From now on your pool will only be a source of relaxation and well-being because the TRi salt water
chlorinator will free you from the constraints of manual treatment while bringing you clean, limpid and more
natural water throughout the season.
We recommend that you read this booklet carefully before installing and using your TRi salt water chlorinator.
Package contents 24
Recommendations 24
Installation guide 25
3.1/ Installing the TRi control box 25
3.2/ Installing the TRi cell 26
3.3/ Installing the ow sensor 26
3.4/ Connecting the TRi control box 27
3.5/ Description of the TRi control panel 27
3.6/ Changing language 28
3.7/ Seing the clock 28
TRi Salt water chlorinator seings 29
4.1/ Commissioning the TRi salt water chlorinator 29
4.2/ e Timers 29
4.3/ Seing the timers 29
4.4/ Clearing the seings 30
4.5/ External clock (ltering command box) 30
4.6/ Adjusting chlorine production 31
4.7/ Low mode 31
4.8/ Boost mode 32
Connecting to an external controller (Home automation) 33
5.1/ Seing the external controller type 33
5.2/ Precautions when wiring an external controller 33
5.3/ Wiring the external controller 34
5.4/ Polaris EOS/ Jandy Aqualink controllers 35
5.5/ Pentair Intellitouch controllers 35
5.6/ Checking wiring 35
5.7/ Checking connections 35
Water balance 35
Diagnostics Menu 36
Error and warning messages: interpretation 36
8.1/ ‘CHECK SALT 36
8.2/ ‘NO FLOW 36
8.3/ ‘CHECK CELL 37
8.4/ ‘OUTPUT FALT 37
8.5/ ‘CLEANING’ 37
Maintenance 38
Use safety 39
Guarantee 40
2
1
3
4
5
6
7
8
9
10
11
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - Contents

23ContentsWe would like to thank you for having chosen the ZODIAC TRi salt water chlorinator for your pool maintenance.From now on your pool will on

Page 2 - Recommendations

32Standard connection diagram:NOTE: e “Low” mode cannot be manually deactivated once it has been automatically started by the closureof the cover. To

Page 3 - Installation guide

>>335>>SelectMenuSelectConnecting to an external controller (Home automation)If you use a centralised control system (or an external contr

Page 4 - 3.2 Installing the TRi cell

34 5.3 Wiring to an external controllerIMPORTANT: e following instructions should be read in conjunction with the external controller

Page 5

355.4 Polaris EOS/ Jandy Aqualink controllers:Green wire (0V) on the ‘0V’ TRi terminalRed wire (+V) on the ‘POS’ TRi terminalYellow/white wire (B) o

Page 6 - 3.7 Seing the clock

>>367Diagnostics menue Zodiac TRi chlorinator automatically warns you in the event of a problem or a fault by displaying a message onthe screen

Page 7 - 4.3 Seing the Timers

ON/OFF37¬Solutions : - Check the pump, the lter and the skimmer(s). Clean them if necessary.- Check the correct operation of the ow sensor.- Check t

Page 8 - 4.4 Clearing the seings

38MaintenanceTo keep your TRi appliance in the best condition we recommend that you maintain it regularly.Inspecting and cleaning the electrodeIn zone

Page 9 - 4.7 Low mode

39ON/OFF10Use safety¬e Zodiac TRi must be installed by a pool professional. Its installation and use must comply with therecommendat

Page 10 - 4.8 Boost mode

4011Guaranteea > ConditionsWe have taken great care and used our technical experience to manufacture this equipment which is the subject ofnumerous

Page 11

24Package contentsa. 1 x TRi control box with one male AUS format plugb. 1 x TRi cell with screw connectorsc. 1 x wall mount with aachment kitd. 2 x

Page 12

25Before performing installation, disconnect all power. Connect to a circuit that is protected by a ground fault circuit interrupter (GFCI). Service t

Page 13 - Water balance

263.2 Installing the TRi cellWARNING: e cell should always be the last device placed on the pool return pipe (see abovediagram).1.

Page 14 - Diagnostics menu

273.4 Connection to the TRi command boxe Zodiac TRi salt water chlorinator is designed to operate exclusively using a 220-240 V ac 50 Hz powersuppl

Page 15 - 8.5 ‘CLEANING’

>>Select>>>>28SelectSelectMenuMenu>>MenuMenuSelect>>Select3.6 Changing the languageOut of the factory your TRi salt wa

Page 16 - Maintenance

ON/OFF429>>Menu>>SelectTRi salt water chlorinator seings4.1 Starting up the TRi salt water chlorinatore TRi chlorine production can be

Page 17 - Use safety

ON/OFF30>>>>>>>>>>>>MenuSelectSelectSelectSelectSelectSelectMenuSelectPress .Use the

Page 18 - Guarantee

31>>4.6 Adjusting chlorine productione amount of chlorine needed for your pool depends on several parameters such as the pool volume, the num

Comments to this Manuals

No comments