the absence of local codes, refer to the latest edition of
the National Electric Code (NEC) in the United States
and the Canadian Electric Code (CEC) in Canada for
installation.
1.5 Technical Assistance
Consult Jandy Technical Support Department or
your local Jandy dealer with any questions or problems
involving the specifications, installation, and operation
of your Jandy equipment. An experienced technical
support staff is ready to assist you in assuring the proper
performance and application of Jandy products. For
technical support call the Jandy Heat Pumps Technical
Service Department at (954) 970-4800
1.6 Materials Needed For Installation
1.6.1 Materials for All Installations
The following items are needed and are to be
supplied by the installer for all heat pump installations:
1. Plumbing connections (2”).
2. Level surface for proper drainage.
3. Suitable electrical supply line. See rating plate on
unit for electrical specications. A junction box is
not needed at the heat pump; connections are made
inside of the heat pump electrical compartment.
Conduit may be attached directly to the heat pump
jacket.
NOTE: Flex conduit is recommended for connecting
the electrical supply wires to the heat pump so
that the front panel may be removed easily for
servicing.
4. Electric cutout switch that will interrupt all power
to the unit. This switch must be within line of sight
of the heat pump.
5. Watertight conduit to run the electrical supply line.
1.6.2 Recommended Materials for
Installations
Jandy recommends installing isolation valves
on the inlet and outlet water connections for ease of
serviceability.
1.7 Specications
1.7.1 General Specications
Installation Location
Certified for use in:
USA
Canada
Mexico
Central and South America
Indoor/Outdoor
approved
Indoor/Outdoor
approved
Indoor/Outdoor
approved
Indoor/Outdoor
approved
Water Pipe/Heater Connection
Plastic 2” PVC (Unions
included)
Flow Rate
Maximum
Minimum
125 gpm
(475 lpm)
30 gpm
(110 lpm)
Maximum Working Water
Pressure
75 psi
Electrical Supply
Voltage Requirements
1-Phase
3-Phase
208/230 VAC 60Hz
208/230/380/460
VAC, 50/60 Hz,
(Model dependent)
Amperage Protection
Requirements
AE2000
AE2500
AE3000
1-Phase
40 A
50 A
50 A
3-Phase
30 A
30 A
30 A
1.7.2 Dimensions
See Figure 1 for a diagram showing the heat
pump’s dimensions and for dimensions to critical
connections.
Section 2. Installation Instructions
2.1 General Information
Install the Jandy heat pumps in accordance
with the procedures in this manual, local codes and
ordinances, and in accordance with the latest edition of
the appropriate national code. (See Section 1.4, “Codes
and Standards”.)